Your search for '180' returned 632 results.

Further information - Ōpunake Power Ltd

Flow duration statistics – 180 l/s residual flow (synthetic) 9 8 7 6 5 4 3 2 1 0 10 86.21 9 16.53 7.81 5.1 3.71 2.73 1.97 1.47 1.08 0.74 0.5 8 0.28 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 7 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 6 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 5 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 4 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 3 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 2 0.18 0.18 0.18 0.18 0.18

Annual report 2012-2013

Freshwater physicochemical state of the environment monitoring report - Taranaki Regional Council.

Relationships between MCI, site altitude & distance from source for Taranaki ring plain streams

Popo, Waingongoro, and Waipuku) were excluded from this analysis. Exclusion of these longer rivers and streams produces a stronger relationship page Stark Environmental Report No. 2009-01 7 January 2009 between MCI and distance from the coast for typical RPNP streams, all of which are less than 40 km long (Figure 2). 0100200300400500600 Altitude (m above mean sea level) 0 20 40 60 80 100 120 140 160 180 200 M C I Figure 1

Westown Haulage (additional cleanfill) monitoring 2020-2021

compliance for 86% of the consents monitored through the Taranaki tailored monitoring programmes, while for another 11% of the consents, a good level of environmental performance and compliance was achieved. This report includes recommendations for the 2021-2022 year. 1 This is a second site at 180 Cowling Road, separate from their cleanfill and woodwaste site at 80 Cowling Road that is permitted by consent 9854-1 and reported on

NPDC Water Supplies Annual Report 2022-2023

There was no abstraction from the Waiongana Stream in relation to the Waitara industrial supply (consent 0126-5) during the 2022-2023 monitoring period (used for contingency only). 2.4.2 Stream flow data 2.4.2.1 Okato Water Supply Consent 0026-4, to take water from the Mangatete Stream for public water supply purposes, includes the following two conditions: Condition 10 When the mean daily flow in the Mangatete Stream at the Saunders Road bridge is less than 180 L/s for a period

Summer 2015-2016

Freshwater recreational bathing monitoring report - Taranaki Regional Council.

Summer 2009-2010

97/98 98/99 99/00 00/01 01/02 02/03 03/04 04/05 05/06 06/07 07/08 08/09 09/10 Minimum Maximum Median 3 899 32 12 740 46 7 200 79 7 140 25 1 90 14 31 980 110 9 2200 92 20 5500 120 <3 220 11 6 380 68 7 3000 72 54 1200 180 51 6000 220 23 3600 100 Figure 4 Box and whisker plots for all summer SEM surveys of E coli

Monitoring results, Town Wharf, summer 2016-17

(NZST) (mS/m) E. coli (cfu/100ml) Enterococci (cfu/100ml) Faecal coliforms (cfu/100ml) (°C) (NTU) 01.11.16 1000 579 260 9 270 14.5 11 30.11.16 1005 179 2500 330 2500 15.5 120 05.12.16 1305 270 84 11 92 20.9 11 12.01.17 0845 477 260 48 260 19.9 5.6 30.01.17 1025 644 270 68 280 18.3 12 01.02.17 1145 422 180 52 180 18.8 6.4 10.02.17 0900 503 250 120 250 18.2 7.0 16.02.17 1220 579 130 64 140 19.0 12 27.02.17 1025 765 150 88 150 19.5 6.2

Freshwater physicochemical monitoring 2017-2018

2003 to June 2018: Maketawa Stream at Tarata Road Parameter Unit Min Max Median N Std Dev A340F Absorbance @ 340nm filtered /cm 0.002 0.141 0.017 180 0.022 A440F Absorbance @ 440nm filtered /cm 0.001 0.031 0.004 180 0.005 A770F Absorbance @ 770nm filtered /cm 0.000 0.002 0.000 180 0.000 ALKT Alkalinity total g/m3 CaCO3 5 34 28 180 6 BLACK DISC Black disc transparency m 0.09 5.23 2.55 180 1.15 BOD5 Biochemical oxygen demand 5 day g/m3 <0.5 5.4 <0.5 180 0.5 CONDY Conductivity @ 20°C mS/m